Operating features
Rated voltage Uo/U is 450/750V(600/1000V).
Allowed continuous working temperature of conductor is 90℃
Installation temperature of cables should be no less than 0℃ . Bending radius should be not less than 12 times O.D. of cable.
Max. Temperature of conductor (Max. 5sec. duration) should be not more than 250℃ .
	
	
1. Application
The cables are designed for connection wires of power distribution equipment for controlling, monitoring, protecting circuits with A .C. rated voltage 450/750V (0.6/1kV)and below.
2. Standards
GB/T9330-2008 ,IEC 60502, etc.
*Ruitian can also design and produce for special application requirement.
category:Controlled Shielded Cable
3. Operating features
3.1 Rated voltage Uo/U is 450/750V(600/1000V).
3.2 Allowed continuous working temperature of conductor is 90℃
3.3 Installation temperature of cables should be no less than 0℃ . Bending radius should be not less than 12 times O.D. of cable.
3.4 Max. Temperature of conductor (Max. 5sec. duration) should be not more than 250℃ .
4. Type,description and main application Table
	
| Chinese Type | Description | Main Application | 
| KYJV | 
					Copper conductor XLPE insulated and PVC sheathed control cable  | 
				
					Laying indoors,in trenches, in ducts and directly in ground  | 
			
| KYJVR | 
					Copper conductor XLPE insulated and PVC sheathed flexible control cable  | 
			|
| KYJVP | 
					Copper conductor XLPE insulated and PVC sheathed control cable with copper tape lapping screen  | 
				
					Laying indoors,in trenches, in ducts directly in ground and other places that interference-resistance is requested.  | 
			
| KYJVP2 | 
					Copper conductor XLPE insulated and PVC sheathed flexible control cable with braiding screen  | 
			|
| KYJVRP | 
					Copper conductor XLPE insulated and PVC sheathed control cable with copper tape longitudinal screen  | 
			|
| KYJVRP2 | 
					Copper conductor XLPE insulated and PVC sheathed flexible control cable with copper tape lapping screen  | 
			|
| KYJV22 | 
					Copper conductor XLPE insulated and PVC sheathed control cable with steel tape armour  | 
				
					For flxed installation,laying indoors, in trenches and ducts,directly in ground where heavier mechanical force withstood  | 
			
| KYJV32 | 
					Copper conductor XLPE insulated and PVC sheathed control cable with steel wire armour  | 
				
					For laying indoor, in tunnels, ducts, conduit and direct burial etc. Permanent place, able to bear greater mechanical force  | 
			
| KYJVP2-22 | 
					Copper conductor XLPE insulated and PVC sheathed steel tape armored control cable with copper tape lapping screen  | 
				
					For fixed installation, laying indoors, in trenches and ducts,directly in ground where heavier mechanical force and interference resistance withstood  | 
			
NOTE: Ruitian can produce “Flame-Retardant Series”, “Fire-Resistant Series”, “Low Smoke Halogen Free (LSHF/LSOH) Series”,“Low Smoke Low Halogen (LSLH) Series”, etc. control cable as customer required.
Performance in line with IEC60332: 2004 requirements.
5. Production range
| Type | 
					Rated voltage V  | 
				Nom.area of conductor (m㎡) | ||||||
| 0.75 | 1.0 | 1.5 | 2.5 | 4 | 6 | 10 | ||
| No.of cores | ||||||||
| KYJV | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVR | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVRP | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVP | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVP2 | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVRP | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVRP2 | 450/750 | 2~61 | 2~61 | 2~61 | 2~14 | 2~14 | 2~14 | 2~10 | 
| KYJVPT | 450/750 | 2~61 | 2~61 | 2~61 | 4~14 | 4~14 | 4~14 | 4~10 | 
| KYJVPL | 450/750 | 7~61 | 7~61 | 4~61 | 4~14 | 4~14 | 4~14 | 4~10 | 
| KYJVP2-22(A) | 450/750 | 4~61 | 4~61 | 4~61 | 4~14 | 4~14 | 4~14 | 4~10 | 
| KYJVPT-22(A) | 450/750 | 4~61 | 4~61 | 4~61 | 4~14 | 4~14 | 4~14 | 4~10 | 
| KYJVPL-22(A) | 450/750 | 4~61 | 4~61 | 4~61 | 4~14 | 4~14 | 4~14 | 4~10 | 
KYJV type 450/750V(0.6/1kV) copper conductor XLPE insulated and PVC sheathed control cable to GB/T9330-2008